Go to our Home Page About us Go to your Personal Shopping Cart Search our site for products or information Return to the AquaStar Main Page See our PowerStar Electric Water Heater Main Page See our PowerSream Electric Water Heater Main Page See our Atiston Electric Under Sink Water Heater Main Page Leave us a message - about products or whatever! See our Specials Page See our Radiant Heating Main Page See our Hydronic and Heating Supply Main Page See our Direct Vent Room and Space Heaters Main Page See our Filter Main Page See our Lighting Main Page See our Tool Main Page See our Misc Product Main Page We accept Visa, MC, American Express Cards

Installation Info for the AquaStar 240FX Water Heater

Return to AquaStar Main Page



Follow information provided on this page.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.


  • Required clearances for OUTDOOR INSTALLATION
MODEL 240FX OUTDOOR INSTALLATION
TOP 36"
FRONT 24" (maintenance space)
BACK 1"
PIPING SIDE 12"
NON PIPING SIDE 6"
GROUND 3" off ground on non-combustible base


  • Required clearances for INDOOR INSTALLATION
MODEL 240FX INDOOR INSTALLATION
TOP 11"
FRONT 4" (24" suggested for maintenance space only)
BACK 1"
PIPING SIDE 6"
NON PIPING SIDE 2"
FLOOR Non-combustible base


  • Gas & Venting for the 240FX
Gas 5/8" 3/4" 7/8" 1"
Liquid Propane Not Recommended 35 feet 70 feet  
Natural Gas   25 feet   80 feet
Venting Min. Diameter Max. Vertical or Horizontal run Max. number of elbows Rule
  4 inches 21 feet 3 Deduct 5ft. for each elbow from max. vent length


  • Dimensions of the 240FX
Height Width Depth Weight
27" 16.5" 8.3" 65 lbs.(shipping weight)


  • Combustion Air Required (Indoor Installations)240FX
In order to ensure an adequate supply of combustion air, the National Fuel Gas Code requires that any conventional vented gas appliance be installed in a room with a minimum volume of 50 cubic feet per 1,000 Btu/hr rated input. The following is the minimum size of the open space in which the 240FX may be installed in compliance with this requirement:

Model Volume Area with an 8' ceiling
240FX 8,250 cubic feet 1,031 square feet

If the 240FX is installed in an area smaller than indicated above, then the installer must make special provisions for combustion air in the form of two openings, each one within 12" of the top and 12" of the bottom of the space, having a total free area of 1 square inch per 1,000 Btu/hr of rated input if the air is taken from inside the house (two 13" x 13" openings). This requirement reduces to 1 square inch per 4,000 Btu/hr if the air is taken from the outside (two 6.5" x 6.5" openings).


Note: This calculation assumes normal rates of "infiltration" of outside air. A super-insulated, super-tight space/building may require outside air for the 240FX even though the volume/area of the space meets this application.

Caution: In addition to the above, the 240FX must be properly vented to ensure safe and efficient operation.


For more information download an
installation 240FX manual in pdf format


Return to AquaStar Main Page